BXFRT - ALKALINE BATTERY/CELL, RT70062M

  • MSDS: BXFRT
  • Manufacturer: BREN TRONICS INC
  • Product Name: ALKALINE BATTERY/CELL, RT70062M
  • National Stock Number: 6135-01-031-8078
Product Identification

Product ID:ALKALINE BATTERY/CELL, RT70062M
MSDS Date:03/01/1991
FSC:6135
NIIN:01-031-8078
MSDS Number: BXFRT

Responsible Party
BREN-TRONICS INC
10 BRAYTON CT
COMMACK, NY 11725
US

Emergency Phone: 516-499-5155

Info Phone: 516-499-5153

Cage: 51828

Contractor
BREN-TRONICS INC
COMMACK, NY 11725-3104 US

Telephone: 631-499-5155

Cage: 51828

Ingredients

2408F, 1320C. SPEC

CAS: 1310-58-3

RTECS: TT2100000

Fraction By Weight: 5-9%

OSHA PEL C 2 MG/M3

ACGIH TLV: C 2 MG/M3

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


CLEAR LIQUID.

RTECS: 9999999ZZ


995F,

CAS: 1313-13-9

RTECS: OP0350000

Fraction By Weight: 32-38%

OSHA PEL 5 MG MN/M3 CEILING

ACGIH TLV: 5 MG MN/M3


1665F, 907C. SPEC

CAS: 7440-66-6

RTECS: ZG8600000

Fraction By Weight: 11-16%

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


GREY POWDER.

RTECS: 9999999ZZ


675F, 357C. SPEC

CAS: 7439-97-6

RTECS: OV4550000

OSHA PEL C, 0.1 MG/M3

ACGIH TLV: S,0.025 MG/M3

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


AMALGAM W/ZN.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THESE CHEMS ARE CNTND IN SEALED CAN.
RISK OF EXPOS OCCURS ONLY IF BATTERY IS MECH/ELEC ABUSED. MOST
LIKELY, RISK IS WHEN CELL LEAKS. KOH IS CAUSTIC & SKIN CONT CAN
CAUSE IRRIT. EYE CONT W/KOH MAY CAUS E PERM INJURY. SKIN & EYE CONT
W/KOH MAY CAUSE BURNS. AT ELEVATED TEMPS HG VAP MAY BE PRESENT &
SHOULD (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:NOT BE INHALED. MERCURY & CMPDS
APPEAR ON THE NAVY LISTING OF OCCUPATIONAL CHEMICAL REPRODUCTIVE
HAZARDS. SEEK CONSULTATION FROM APPROPRIATE HEALTH PROFESSIONALS
CONCERNING LATEST HAZARD LIS T INFORMATION AND SAFE HANDLING AND
EXPOSURE INFORMATION .
Medical Cond Aggravated by Exposure:AN ACUTE EXPOSURE WILL NOT
GENERALLY AGGRAVATE ANY MEDICAL CONDITION.

First Aid

First Aid:INGEST:CALL MD IMMEDIATELY . INHAL:REMOVE TO FRESH AIR.
SUPPORT BREATHING (GIVE O*2/ARTF RESP) . SKIN:FLUSH WITH WATER AND
WASH WITH SOAP AND WATER. EYES:FLUSH WITH COPIOUS AMOUNTS OF WATE R
FOR AT LEAST 15 MINUTES THEN SEE PHYSICIAN AT ONCE.

Fire Fighting

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:CELLS MAY RUPTURE WHEN HEATED
EXCESSIVELY; MAY RELEASE TOXIC MERCURY AND CORROSIVE MATERIALS WHEN
INTEGRITY OF CELL CAN IS BROKEN.

Accidental Release

Spill Release Procedures:AVOID SKIN AND EYE CONTACT. DO NOT INHALE
VAPORS. COLLECT ALL RELEASED MATERIAL IN PLASTIC BAG FOR WASTE
DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN DRY PLACE. DO NOT RECHARGE.
DO NOT SHORT CIRCUIT.
Other Precautions:USE BATTERY ONLY IN PROPER EQUIPMENT. OBSERVE CORRECT
POLARITY WHEN INSTALLING INTO EQUIPMENT. DO NOT ATTEMPT TO
RECHARGE.

Exposure Controls

Respiratory Protection:AS IN ANY FIRE SITUATION, USE NIOSH/MSHA
APPROVED SELF-CONTAINED BREATHING APPARATUS (SCBA).
Ventilation:NOT APPLICABLE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:NOT APPLICABLE.
Work Hygienic Practices:NOT APPLICABLE.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Boiling Pt:B.P. Text:SEE INGS
Melt/Freeze Pt:M.P/F.P Text:SEE INGS
Vapor Pres:SEE INGS
Spec Gravity:SEE INGS
Solubility in Water:SEE INGREDIENTS.
Appearance and Odor:SEE INGREDIENTS.

Stability

Stability Indicator/Materials to Avoid:YES
NOT APPLICABLE.
Stability Condition to Avoid:DO NOT HEAT, DISASSEMBLE, OR RECHARGE. DO
NOT SHORT CIRCUIT.
Hazardous Decomposition Products:WHEN HEATED, CELLS MAY EMIT HAZARDOUS
VAPORS OF HG OR CAUSTIC KOH.

Disposal

Waste Disposal Methods:IN SMALL QUANTITIES, BATTERIES MAY BE DISPOSED
OF WITH HOUSEHOLD TRASH. DO NOT INCINERATE. DISPOSE OF LARGE
QUANTITIES IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGUALTIONS
.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.